RELAY PROTECTION ELECTRICAL @UCs7vZxJY-WHeFh3_I9IjQoA@youtube.com

13K subscribers - no pronouns :c

Hi friends this channel is all about sharing of my experienc


17:56
Over current Relay Coordination for a Sub Station|| Case-2
06:24
Case Study: Differential Relay || Trip Phase A and Phase B
21:19
OVER CURRENT RELAY COORDINATION IN A SUB STATION || TWO NOS TRANSFORMERS RUNNING IN PARALLEL||Case-I
06:03
DISTANCE RELAY || Primary to Secondary Impedance Conversion
04:57
Over Current Relay Coordination in a Sub Station
08:34
Current Transformer (CT) Polarity and Methods for Changing CT Polarity for Protection system
11:09
Function of DC Selector Switch in Control and Relay Panel for double DC source
08:00
Line Earth Switch (89LE) Interlock for Transmission Line in a Sub Station
09:26
PT(Potential Transformer)Selection Scheme for Two Main Bus System ( 75A and 75B Relay)
12:21
Current Transformer (CT) Wiring Diagram for Metering Circuit in CRP for FDR
07:27
Importance of Core Selection Test of CT|| What will happen if Metering Core is Connected to Relay
06:07
Difference between Isolator and Circuit Breaker in a Sub Station
09:35
Current Transformer (CT) ISF(Instrument Safety Factor) V/S ALF (Accuracy Limit Factor)
07:50
Protection of Teed Feeder for Transmission Line || Overcome Difficulty for Distance Relay Settings
11:33
11 KV VCB CLOSING AND TRIPPING OPERATION WIRING DIAGRAM
11:32
Current Transformer (CT) Wiring Diagram for 11KV Switch Gear Panel
10:02
Trip Transfer Scheme for Sub Station|| How trip is Transferred to TBC Breaker
09:19
Directional Over current Relay and Cross Polarization Method
10:02
Impact of Different Transformers with different Percentage Impedance under Parallel Operation
04:59
Difference Between High Impedance BusBar Protection Relay and Low Impedance BusBar Protection Relay
06:07
End Fault Protection or Dead Zone Fault Protection for Bus Bar Relay
09:48
BUS Bar Protection for Two Main Bus and One Transfer Bus System (Part-3)
14:44
BUSBAR PROTECTION FOR TWO BUS SYSTEM (PART-2)|| CONCEPT OF CHECK ZONE DIFFERENTIAL CURRENT
18:54
Bus Bar Protection for Two Bus System (Part-1)
11:11
Motor Earth Fault Relay||Stabilizing Resistance Rs for Motor Earth Fault Protection
09:14
Earth Fault Relay Setting|| Impact of wrong Coordination for Earth Fault in Distribution System
06:42
3-Phase Motor Protection|| Single Phase Preventer(SPP) for protection of Motor from phase Failure
07:00
Fault Level Calculation for 33 KV Bus || 3-Ph Symmetrical Fault
07:00
How Much Winding is Protected by Differential Relay for Fault in Star Side of the Transformer
04:15
How to Calculate Lightning Arrester (LA) Rating for different System Voltage
07:35
Fault Current Calculation for Transmission Line and Simulation in ETAP
07:38
Fault Current Calculation and Simulation in ETAP for Parallel Operation of Transformer 33/11kV 10MVA
01:53
What is Differential Zone for Transformer
08:47
Zero Sequence Current Filtering for Differential Relay of Power Transformer
13:30
BACK UP OVERCURRENT AND EARTH FAULT PROTECTION OF TRANSFORMER WITH RELAY COORDINATION
06:07
Transformer Testing|| Tan Delta Test of Transformer Winding|| UST, GST and GSTg mode in Hindi
12:57
Static Differential Relay|| How phase and Magnitude Correction is done by using ICT
08:02
Different Parts of 11 KV VCB ( VACCUM CIRCUIT BREAKER) Switchgear and their Functions
10:10
RESTRICTED EARTH FAULT RELAY LOW IMPEDANCE TYPE || OPERATING PRINCIPLE
14:38
RELAY COORDINATION || MPACT OF WRONG RELAY SETTINGS COORDINATION IN DISTRIBUTION SUB STATION
07:19
Current Distribution In a Delta Star Transformer for 3-PH , Double Phase and Phase to Ground Fault
07:38
Transformer Protection|| Function of Buchholz Relay || Buchholz Alarm and Buchholz Trip
12:59
Transformer Testing|| Magnetisation Current Test of 3 PH Transformer (in Hindi) हिंदी में
10:59
Function of CVT ( CAPACITIVE VOLTAGE TRANSFORMER) IN A SUB STATION
13:36
Distance Relay|| Impact of Kz Zero Sequence Compensation Factor Distance Relay Reach for Earth Fault
10:28
CT Polarity and CT Star Point Connection for Transmission Line Protection in Hindi
08:11
ISF (Instrument Security Factor) and CT Burden for Metering Class Current Transformer
09:29
Matching Factor and Per Unit (PU) Current for Differential Relay (in Hindi) हिंदी में
08:46
Matching Factor and Per Unit (PU) Current for Differential Relay
11:36
Discrepancy Relay 30X|| CB (Circuit Breaker) Discrepancy Circuit || Function of CB discrepancy Ckt.
06:42
Load to Power Conversion Without Using Calculator || Ampere to MW Conversion 👍 Rule ( in Hindi)
05:55
Impact of Broken Neutral in Distribution System ( in Hindi)
08:38
3- Ph. Fault V/S 1- Ph. to Earth Fault ||Which One is Severe || Fault Current in Transmission System
07:52
Difference between 5P10 and 5P20 CT and Importance of Class P CT Accuracy Limit Factor (ALF)
09:31
Difference between High Impedance REF Protection and Low Impedance REF Protection Relay
07:10
Battery Bank in a Sub Station|| Function of Tap Cell || Float and Boost Charging
10:27
Current Transformer Accuracy Class for Metering Class 0.2 and 0.2 S and Class 0.5 and 0.5S
10:40
Insulation Resistance Test of Transformer|| DAR ( Dielectric Absorption Ratio) and PI
07:21
Trip Circuit Supervision by means of Numerical Relay Binary or Opto Input (in Hindi)
09:02
Current Reversal Guard Logic in Permissive Overreach Transfer Trip ( POTT ) Scheme in Distance Relay