Channel Avatar

HVACR AUS @UChPEEMOtIdr0axJ1FggP_Dw@youtube.com

2.8K subscribers - no pronouns :c

Commercial HVACR technician from Melbourne, Australia. Enq


12:18
Mitsubishi Electric / I Finally Return With The Bell Mouth Cowls
11:26
Daikin VRV 5 / U4 & E7 Faults
11:46
Daikin / High-wall Split System Won’t Turn On
24:49
Temperzone / More Issues With This 55kW Package Unit
17:05
Mitsubishi Electric / City Multi VRF 7102 Fault
21:28
Daikin VRV II / Heat Recovery System Has Performance Issues
10:48
A Few Jobs From Multiple Site: Ep 5
12:17
Daikin VRV 6 / My First Time Connecting the Type 4 Checker to a Daikin VRV R
28:02
Actron Air / Two New Package Units with E45 Faults
15:24
A Few Jobs From Multiple Sites: Ep 4
13:19
EmailAir / Outdoor is a Block of Ice
17:44
Actron Air / Airflow Issues on a 71kW Tri-Capacity Package Unit
24:52
Temperzone / I Had the Replacement Outdoor Fan Only to Find the PCB Was Now Blown
24:29
Mitsubishi Electric / Leak Search on a City Multi PURY-YNW
09:48
FCU isn’t Heating the Surgery Room
10:31
Daikin / Compressor is Ramping Down After 10 Minutes
13:11
Multiple Issues at One Site
15:56
Temperzone / Replacing a Drive Pulley on a 65kW Package Unit
13:27
Daikin VRV-S / New VRV-S System isn’t Heating the Space
20:11
Daikin / 27kW Package Unit is Covered in Ice
11:59
Fujitsu Airstage / Pumping Down a 3 Pipe VRF to Add an Extra Indoor Unit
18:15
Apac / System Ran But Then Blew an Outdoor Fuse
23:17
Mitsubishi Electric / Fan Replacement on a PUHZ-YKM & Static Pressure Measurements
22:28
Mitsubishi Electric / Replacing the Outdoor Coil on a City Multi VRF
21:41
Daikin / Repairing an E3 Fault on a Multi Inverter
14:12
Mitsubishi Electric / City Multi VRF 6831 Fault Turned into a Lot More
15:54
Mitsubishi Electric / City Multi VRF Leak Repair - Part 3
23:54
Mitsubishi Electric / City Multi VRF Leak Repair - Part 2
06:57
Mitsubishi Electric / City Multi VRF Leak Repair - Part 1
12:24
Temperzone / Split Ducted System not Cooling
13:23
Multiple Air Conditioners Are Down
12:28
The Walk-in Freezer Has a Few Issues
17:23
Mitsubishi Electric / City Multi VRF 5015 Fault
14:15
Servicing My Ducted Air Conditioner
13:51
Daikin VRV III / Inverter Compressor & PCB Replacement on a VRV System - Part 2
18:45
Daikin VRV III / Inverter Compressor & PCB Replacement on a VRV System - Part 1
14:16
Actron Air / Commissioning a 25kW Package Unit
15:39
A Few Jobs From Multiple Sites: Ep 3
12:22
Mitsubishi Electric / City Multi VRF 6607 Fault
08:09
A Few Jobs From Multiple Sites: Ep 2
19:07
LG MultiV 5 / Recommissioning an LG VRF System
14:11
A Few Jobs From Multiple Sites: Ep 1
07:39
Mitsubishi Electric / Multi Head System Runs and Then Turns Off
12:35
A Day of Service Calls
10:33
Temperzone / Replacing Two Faulty UC8 PCB’s
29:22
A Few Jobs From One Site
17:02
Day With a Commercial HVACR Tech
06:20
Walk-in Cool Room Appears to Have Issues
12:47
Temperzone / Split Ducted System not Working
08:00
Mitsubishi Electric / Installing a 2.5kW High-wall Split System
33:02
Walk-in Freezer Installation
11:46
Bradway / Replacing The Outdoor Fan Motor and Pressure Control on Stage 1 of This Package Unit
10:50
Mitsubishi Electric / High-wall Split System Will Not Respond to the Remote
17:58
Daikin VRV IV / When I Returned To Commission the System Wouldn’t Respond
13:16
Temperzone / Package Unit is Out On High Pressure Lockout
08:48
Mitsubishi Electric / The Thermostat is Blank and The Kitchen is Hot
11:59
York / Finding and Repairing a Refrigerant Leak on This Package Unit
15:44
All Air Conditioners are Down After a 38 Degree Day
14:09
Replacing a Patton Evaporator
09:39
Daikin VRV IV / Recovering 50kg’s of R410A out of This Daikin Multi Condenser System