Channel Avatar

Pure Electrical Training - by Adrian Davey @UChuc3MSl3Crwg6gkeHxd6-w@youtube.com

12K subscribers - no pronouns :c

Welcome to my channel. My name is Adrian and I started my a


19:03
Verify R1 + R2 testing of a radial lighting circuit - covers fault finding and write-up. Part 1 of 3
07:10
resistors in series part 3 of 3 - Calculating the current total using voltage drop over a resistor
15:23
Resistors in series part 1 of 3 - Why we need to know resistors in series and how we use it on-site
07:53
resistors in series part 2 of 3 - How to calculate your missing values
06:11
Earthing and bonding part 3 - Fault finding bonding and earthing conductors
05:18
Review of Contactum 6-way consumer unit with 100A main switch. SDD061MS
10:20
Have you fallen foul of a rogue trader? I have a solution
12:44
Why we need change in the electrical industry and my GoFundMe page
11:19
Earthing and bonding part 2: How to test continuity of protective conductors
12:27
Earthing and bonding part 1: what are main and equipotential bonding conductors
23:37
Boiler wiring made easy
10:29
Understanding and recognising UK electrical earthing arrangements - inspection and testing & Design
31:07
Become an electrician and get a gold card the easy way on the CG2346 experienced worker route
20:07
How to correctly terminate bonding straps - life hack. Also covers easy clamps from AM2
09:22
Inspection and Testing - Ring final circuit figure of 8 explained
10:59
Inspection and Testing - End-to-end testing of a ring final circuit. AM2 CG2391
04:51
your AM2 Facebook group
19:09
Fault finding on a Ring Final Circuit using R1+R2 & R1+RN, the only way to prove polarity AM2 AM2S
03:28
Transposition made easy video 4 - Electrical Science and principles 1st year exam
12:47
Transposition made easy video 3 - Electrical Science and principles 1st year exam
15:28
Transposition made easy video 2 - Electrical Science and principles 1st year exam
18:59
Transposition made easy video 1 - Electrical Science and principles 1st year exam
06:48
How to chase in a double socket with minimal damage to wall
29:05
Inspection and Testing R1 + R2 and fault finding
17:32
1b. Safe isolation and EAWR 1988 Part 2 - Where and how to safely isolate. Helps AM2, CG 2391 etc.
19:20
1a. Safe isolation and EAWR 1989 Part 1 - How safe isolation complies and dangers of electric shock
34:40
1. Safe isolation and EAWR before testing, why, where and how (Part 1 & 2 full video)
05:36
How to make a socket nulling adapter for your tool bag
30:08
Prescribed zones, chase depths and why I think most installers are not following the regulations
29:12
How to make apprenticeships work for you at any age: Video with Solent Apprenticeship hub Part 3
12:23
Benefits of a Traineeship, and integrating it into the beginning of the apprenticeship process?
33:23
£4K to take on an apprentice: Solent apprentice hub provide the information and incentives you need
18:29
Death of the 18 day domestic electrical course
02:25
One of the biggest mistakes that I made as an electrical apprentice
36:16
Becoming an electrician: Jake is looking to change career and had questions for the CG2365 diploma
34:10
Becoming an electrician: Sachin's experience on the full time EAL level 2 diploma route
19:19
Video 3 of the 2346 AM2E experienced worker /5357 workplace logbook NVQ unit 106 talk through
16:59
Level 2 and 3 electrical diploma routes - What you need to know. CG2365; 8202; and EAL equivalent
24:02
Neil Phillips and I talk through the pro's and con's of the existing electrical training routes Pt1
43:43
Mathew’s domestic installer route into the industry
38:50
Becoming an electrician via the City and Guilds 2365 diploma route? This is Aidan's experience
18:52
How to connect up 1-way and 2-way lighting with a fan
38:58
Trying to Become an Electrician through the City and Guilds 2365 route, this is Dex's experience.
30:03
Want to become an electrician? Lee chose the domestic installer route and this is his story
42:42
Looking to become an electrician in the UK? Lawrence's career change MOD self funded route or AM2E
36:24
Looking to become an electrician in the UK? Paul did the diploma route and this is his experience
04:24
Are you testing insulation resistance of a domestic installation properly? I now know I wasn’t!
09:03
shortage of electricians in the UK; fact or fiction?
01:14:08
Incompetent and dangerous EICR's, the Electricity at Work Regulations, and are the public in danger?
15:33
Are you ready for the AM2 or AM2S
29:34
Video 2 of 5357 and 2346 AM2E experienced worker Unit 102 Health and Safety workplace logbook NVQ
38:07
UK Electrical apprenticeship route compared to the self funded diploma route, what you need to know
55:48
How to become an electrician UK, what you need to know before you make your decision
44:42
How to position down lights and check for joists
10:06
Are you qualified as an electrician?
33:33
City and Guilds 5357 / 8202 / 2365 /2346 AM2E experienced worker portfolio NVQ/ Workplace Logbook
07:31
Let’s talk about safe isolation
13:57
Test Instrument Solutions video 5 - TIS 859 voltage indicator, continuity tester and so much more
13:27
Test Instrument Solutions video 4 - TIS 851 full safe isolation kit
08:16
Test Instrument Solutions (TIS) Video 3 - TIS Lamp adapters