Construction Building Codes and Standards


01:28
Electrical underground and excavation failure per ibc 3304.1.1
02:36
Fuel dispensers review nec sections 514.11(a), 514.9(a), 514.8 exception #2, & table 514.3(b)(1).
02:04
Fuel stations & Hazardous areas per nec table 514.3(b)1. See 514.9 and 514.8 exc#2.
01:29
Exhaust duct vrs air distribution duct per section 603.9
01:10
System bond jumper and grounding per section 250.102(d), 250.104, 250.52
01:03
Roof rafters over spanned per rafter table review section r802.4 and figure r802.4.5
01:18
Cantilever and deck extension not to code per American wood council prescription deck guide
01:17
Shaft liner installation per manufacturer instructions
02:06
Fire barrier violation missing continuity. Review ibc 708.4, 707.8, 707.9 707.6 , 707.3.10, & 718.2
01:08
Stairway Clear with violation review ibc section 1010.1.1.1, 1009.3.2, 1011.6 & 1014.8
02:25
Box fill and conductor allowance exceeding table 314.16(a) and table 314.16(b).
01:41
Attic draftstopping not installed per ibc section 718.4. Review section 718.3.1 and 1208.2 also.
01:04
Deck supports not installed per American wood council deck guide or irc section r507.
02:03
Exits per story and occupancy ibc table 1006.3.2. Top and bottom plate anchor per ibc 1604.8
02:07
Wood truss and roof decking installation per Apa form r275a and irc r802.10.1, r802.10.3, r802.11.1
01:27
Exothermic weld process for a Delta supplement ground per nec 250.64(c) note(1)
01:54
Electrical Conduit placement in elevated slabs
01:02
Hairpin pt cable placement for elevated slab
01:32
Concealed wood framing fire locking per irc r302.11
01:41
Open web floor systems missing draftstopping per irc r302.12 also missing horizontal fire blocking
01:18
Repair work verify iebc section 405.2.3.1, 405.2.3.3, 302.4, 302.5.1, & 403.1
01:03
Elevated deck inspection and rated sleeves per manufacturer and nec 352.24
01:17
Transformers and ventilation per nec 450.9 and 450.10(a)&(b)
01:23
Garage portal openings see figure r606.10.6.4.
02:11
bathroom glazing installed per irc r308.4.5 missing flush mounted box per nec 314.20 & 210.8.
03:20
Oversized overcurrent device for equipment per nec 440.22(c), 440.6(a), & id not clear per 110.22(a)
00:34
Visible alarm synchronization per 18.5.5.4.2 of nfpa 72 & hvac detection tied into general alarm
01:42
Wind exposures and basic code per 2018 irc r301.2.1.4, 302.11, 602.6.1, 802.4.2, g2425.15.4(501.15.4
01:29
Ceiling joist not installed per irc fastener schedule table r602.3(1) & fire blocking per r302.11
01:04
Property lines and rated walls per irc table r302.1(1) and r302.1
01:15
Top plate and intersection per irc section r602.3.2 and see exception r602.6.1
01:39
Existing piers not installed per r404.1.9.2, r404.1.5.3, r401.2, & figure r602.3(2) irc 2018
01:07
Construction standpipes per (f)3311.1 of ibc & 3303.3 see ifc section 3313.1, & 3315
01:02
Insulation protection per r403.4.1, unit nameplates per nec 430.6(2), securing units per imc 301.15
01:03
Public bathroom inspection per nec 210.8(7), section 604.5, 604.6, 604.9.3, 604.7, & 606.6 of a117.1
01:24
Drinking fountain inspection per nec 210.8(11) & 210.8 & 210.5(b),(a)
01:07
Missing Truss bracing and gable end bracing per r802.10.3 & r802.10.2, ibc 2303.4.1.1
01:18
Combustion clearance, ventilation and exhaust per ifgc section 304, 503.10.7, table 503.10.5
01:12
Stairways not installed per ibc 1023.5, 1010.1.6, & 1011.6
01:18
Stair stringers over cut and missing support per irc r311.5 & r311.7.5.1
01:17
Ada bathroom components per 604.9.3, 604.6, 604.9.2.1, 604.7, 604.5, 603.6, 604.2, & 610.4
01:28
Electrical requirements per nec 450.9, 450.11(a)(b), 408.4(a)(b), 110.22(a), 110.24(a), & 110.26(3)
01:13
Pressurization fan smoke shut down test per imc section 606.2, ifc 907.3.1, section 909, & ibc 909.4
01:31
Horizontal fire blocking missing per IBC 718.2.2 / IRC r302.11
01:20
No2 and co2 exhaust fans and sensors per ibc 406.6.2, imc 502.13, & 404.1
01:10
Building set backs , utility marking , trees, and access
01:39
Rated sheathing / Fire wall not required per irc see table r302.1(1), r302.2.3, r302.3, and r302.2.2
02:31
Common residential framing
01:56
Residential se overhead power release
01:19
Residential grounding per nec 250.52(a)(3)&(5) also gas bonding per nec 250.104(b)
01:32
Fire resistance rated walls for residential dwellings
01:52
Carbon and smoke detector interconnected per irc 315.5, r314.6, and r314.4
01:13
Smoke and carbon detectors per r314.2.2 and r315.6
01:08
Step and stair failure per ibc 1011.5.2
01:11
Hvac fire and smoke damper access fail per imc (bf)607.4 and (bf)607.5
01:30
Gas main fail per ifgc 404.11, 404.11.3, and 404.11.2
00:32
Rated doors not latching per ifc 705.2.3 and ibc 1010.1.9.4, 717.2.6.2, and 716.2.6.6
01:06
Door hardware / egress door hardware / ada accessible doors per 404.2.6 and figure c404.2.6
02:33
Continuous pool bond / pool shell / perimeter surface per nec 680.26(a)(b)(1()(2)(3)(4)&(5).
01:05
Attic gfci install exceeding code. Gfci receptacles or over current breakers not required per 210.8